Skip to content
DURASTARTSODIUM-ION TECHNOLOGY
Dealers

DWG DS-001 · Dura Start Battery (Thailand) Co., Ltd.

Sodium-ion power, engineered to spec.

We develop battery management systems, battery packs and sodium battery materials for vehicle start-stop systems. Every number on this page comes from an approved data sheet.

DTZ5S · General arrangementUnits: mm
DTZ5S product photograph
REF. PHOTO
ModelDTZ5S
Nominal12V · 1.7Ah
CCA80A
Weight454 g

Sheet 01 / Technology

Five design principles

Company-level technology positioning, kept separate from model specifications. Where a number appears, it is the DTZ5S value.

A

Sodium-ion chemistry

Sodium battery technology for vehicle start-stop systems, positioned as the next step beyond lead-acid.

DTZ5S · 20.4 Wh

B

High-rate power

Designed for the short, intense current a motorcycle start demands.

DTZ5S · 70C ≤2s @25°C

C

Smart BMS

Discharge, thermal, fault and communication management on board.

See sheet 03

D

Compact & light

A compact ABS case sized for motorcycle battery bays.

DTZ5S · 454 g

E

Sealed & marked

Sealed case with certification marks shown on the model data sheet.

DTZ5S · IP67

Sheet 02 / Product

DTZ5S full specification

Reproduced from the DuraStart DTZ5S data sheet, with every condition kept.

DTZ5S · Sodium-ion · 12V 1.7Ah · CCA 80A
Electrical characteristics
Nominal voltage12V
Nominal capacity1700mAh
Energy20.4 Wh
Internal resistance≤ 35mΩ
Cycle life>3000 cycles @80% DOD
Self-discharge≤5% /month @25°C
Charge
Charge voltage14.8V ±0.2V
Charge current0.5C @15–45°C
0.2C @10–15°C
0.1C @0–10°C
Max. charge current5C @25°C
Charge mode0.5C CC to 14.8V, then 14.8V CV, charge current to 0.05C (CC/CV) @15–40°C
Discharge
Discharge cut-off voltage6V
Discharge current (recomm.)0.5C @25°C
Max. continuous discharge current40C @0–45°C
Instant discharge current70C (≤2s) @25°C
Environmental
Charge operating temperature0–45°C
Discharge operating temperature−40°C – 60°C
Humidity60 ±25% RH
IP ratingIP67
Mechanical
Plastic caseABS
Dimensions113 × 69 × 86 mm ±2 mm
Weight454 g (0.45 kg)

Sheet 03 / BMS & Safety

Inside the pack

Every Dura Start battery pairs sodium-ion cells with a battery management system that monitors, estimates and protects.

CELLSSODIUM-ION BATTERY MANAGEMENT SYSTEM ▸ Discharge management ▸ Thermal management ▸ Fault alarm & protection ▸ Communication management ▸ SOC: Ah integration, OCV correction, Kalman filtering OUTPUT + / − 12VTERMINALS CELL DATAPROTECTED
Over-chargeOver-dischargeOver-voltageOver-current Short circuitHigh temperatureLow temperatureCell balancing

BMS functions from the Dura Start company profile; protection list from client BMS artwork. Copy pending client approval.

Sheet 04 / Range

The DuraStart series

DTZ5S is fully specified. Further models will be published as their data sheets are approved.

Sheet 05 / Company

General notes

  1. Who we are

    Dura Start Battery (Thailand) Co., Ltd. is a high-tech company specialising in sodium battery technology for vehicle start-stop systems, serving Thailand and the wider Southeast Asian market.

  2. Mission

    To drive a cleaner automotive future where every journey begins with sustainable, abundant energy.

  3. Vision

    To lead the future of motorcycle energy in Thailand, becoming the national standard for high-performance start-stop power.

  4. Sustainability

    Replacing conventional lead-acid starter batteries with sodium-ion reduces reliance on lead in everyday vehicles.

Marks · as shown on the DTZ5S data sheet

ISO
9001
ISO
14000
IEC
62133-2
UN
38.3
IP67RoHSREACHMSDSPb-free

Sheet 06 / Partnerships

Request for partnership

Distributors, dealers, workshops, fleet operators and motorcycle-industry partners: tell us about your business and we will get back to you.

Channel
LINE Official @durastart
Social
TikTok · Facebook
Phone
To be confirmed
Email
To be confirmed
Address
To be confirmed